Feature Summary
[Shortcut Command : TCT]
This is a function that converts the coordinates of the Tendon modeled in CIM into coordinates for each location specified by the user and creates a table.
Function Explanation
Generate Drawing > Material List Table > Tendon Coordinate Table
Row / Column
Station : Set the station to generate Tendon coordinates. Based on the path referenced by the Tendon, the location is calculated according to the Station value.
Alternate text : Enter when you want to replace the table column title with other text. The default is displayed as 'Station'.
Unit : Set the Tendon coordinate value Unit.
Precision : Sets the precision of Tendon coordinate values.
Ascending sort : Sorts the table so that the station values are in ascending order.
Descending sort : Sorts the table so that the station values are in descending order.
Input Multi Station : Used to input multiple Station values in batches. For example, it is used when you want to automatically input the Station value in 1 meter intervals from 1 to 100 meters.
Start : Enter the starting value of the Station.
End Station : Enter the End Station value to create Tendon coordinates.
Interval : Enter an interval value to increase the value of Station.
Column : Displays Tendon coordinates in order of Tendon Name or Prestressing Number.
Alternate text : Enter when you want to replace the table column title with other text. The default is displayed as 'Tendon Name'.
Row/Column Switching : Swap rows and columns. In Tendon Coordinate Table, by default, the station is displayed in the row and the coordinates for each tendon are displayed in the column. When this option is selected, the rows and columns are reversed.
Ascending sort : Sorts the table so that the value used as the Tendon Name is in ascending order.
Descending sort : Sorts the table so that the value used as the Tendon Name is in descending order.
Alternate Text (Start/End Anchor) : Enter the value of anchorage angle to change the column title when displaying the table.
Angle Precision : Sets the accuracy of the anchorage angle.