Summary
Create a three-centre tunnel as an Assembly Unit using the library built into the program.
How to Run
[Base Mode]
Ribbon Menu > [Base] Tab > [Library] Group > Template
Tunnel
Explanation
General Tab
Template Name : Enter the name of the Template to be created.
Run Modify Mode after Creation : When set to On, the Assembly Unit Mode automatically runs when the user create creates the template after entering all the settings so that the created template model can be modified.
Layout Tab
[General]
Number of Sections : Enter the number of superelevation slopes of the section required for tunnel modeling. The user can set up to 5 sections.
Number of Segments : Enter the number of segments to apply superelevation slopes. The user can set up to 15 segments.
Total Length : The sum of the segment lengths entered in the Segment Definition, which are automatically entered.
[Configuration]
Superelevation Data : Enter the superelevation data of the section to be created.
The user can enter as many Sections as the user sets in the Tunnel Information.Segment Definition : Enter the lenth of the segment of the superelevation and the superelevation data.
The user can enter as many Segments as the user sets in the Tunnel Information.
Info |
---|
|
Model Tab
Base Section
[Base Section]
In the Base Section, enter the dimensional table value and the resource value for the tunnel section.Road Width : Enter the width of the left and right lanes of the road.
Lining Thickness : Enter the thickness of the lining.
Shotcrete Thickness : Enter the thickness of the shotcrete.
Pavement Thickness : Enter the thickness of the pavement.
Cement Thickness : Enter the thickness of the cement.
Top Angle : Enter the central angle of the 3-centre tunnel.
Layout Offset : Enter the distance from the road centerline to the tunnel centerline.
Example of Dimension Table Values.
Abut Type
[Abut Type]
For Abut Type, set the type of multi-utility on the left and right sides of the tunnel, and enter the resource value for each typeDifferent Abut Type : If set to On, the left and right multi-utility types can be set respectively.
Info |
---|
|
Example of Abut Type value input
Expand | ||||||
---|---|---|---|---|---|---|
|
Support Pattern Tab
Define
[Define]
Enter the setting values for the longitudinal spacing, transverse spacing, and number of Rock Bolts and Grouting shown in the standard support pattern table.
Up to 10 support patterns can be set.Rock Bolt : Enter the pattern name, length, number, longitudinal spacing, transverse spacing, and whether or not grouting is present.
Grouting : The user can enter a value only when Grouting of the Rock Bolt is set.
Enter the number, longitudinal spacing, transverse spacing, separation distance from the lining, angle, and diameter.Radial Arrangement : When set to On, the Grouting is placed radially.
Info |
---|
|
Assign
[Assign]
Enter the support pattern for each segment and the length of the segment where the user wants to enter the support pattern.
For the Support Pattern, the user can select one of the support patterns set in [Define], and up to 20 segments can be set.
Info |
---|
|