Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Table of Contents

Feature Summary

...

Rebar Group Setting [Shortcut command: RG]

...

Table of Contents

Summary

...

  • The Rebar Group Setting

...

  • is a

...

  • feature that selects and expresses only the main rebars among the grouped

...

  • rebars.

Function Explanation

Generate Drawing > Style > Rebar Group Setting

...

 

How to Run

...

[CIM View Mode]

  • Ribbon Menu > [INFRA-DESIGN] Tab> Rebar Group Setting [RG] / Delete Rebar Group Setting [DRG]

Explanation

...

How to Rebar Group Setting

After executing the Rebar Group Setting command, set the main rebar

...

of the

...

group in the order shown in the figure above.
This setting takes precedence over the Group Rebar Type setting of Rebar Style.

...

Note

Assuming that the group position of the reinforcing bar selected as a representative is the 10th, if the number of rebars becomes less than 10 through the model update, the settings are initialized.

...

Rebar Group Setting, Shortcut key : RG

Commentary contents

image-20240624-022319.pngImage Added

  • [Command]
    Execute rebar group setting from the tree menu or enter the shortcut key RG in the command window.

image-20240624-022330.pngImage Added

  • [Command]

    • Select group object :
      Select representative Rebar or [Undo(U)] :
      (lightbulb) Select a grouped rebar group.

image-20240624-022340.pngImage Added

  • Command]

    • Select representative Rebar or [Undo(U)] :
      Entity in set : **
      (lightbulb) Select only the rebars to be represented in the section.

image-20240624-022345.pngImage Added

  • [Command]

    • Select representative Rebar or [Undo(U)] :
      Entity in set : **
      Select representative Rebar or [Undo(U)] :
      (lightbulb) Among the grouped rebars, only the representative rebars are displayed.

image-20240624-022140.pngImage Added

[Command]

  • Rebar Group Setting complete.

Note

After rebar group setting, the settings are initialized when the selected rebar is updated due to a model change, the location changes, or the relevant rebar is deleted.

...

INFRA-DESIGN > Style > Delete Rebar Group Setting

Delete the representative main rebar designation setting.

  • Object : Deletes only the settings of the selected reinforcing bar rebar object.

  • View : Deletes the representative reinforcing bar main rebar settings of all reinforcing bar rebar objects belonging to the selected view.

  • All : Deletes the representative reinforcing bar main rebar settings of all reinforcing bar rebar objects in the current work space workspace (based on the upper tapTab shown above).