Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Table of Contents

Feature Summary

Info

[Shortcut Command : TCT]

This feature converts the coordinates of the Tendon modeled in CIM into coordinates for each location specified by the user and creates a Table from the information provided.

image-20240620-074948.png

Feature Explanation

INFRA-DESIGN > Material Table > Tendon Coordinate Table

Row

Tendon Coordinate Table Settings

image-20240620-075321.png

Tendon Coordinate Table Settings

  • Table Name : Displays the Tendon Coordinate Table style file name.

  • Style : Select the style of the saved Tendon Coordinate Table.

  • Style Save : When saving settings, the Tendon Coordinate Table style is saved in the settings value list.

  • Style Delete : When deleting a setting, the Tendon Coordinate Table style is deleted from the settings value list.

  • Import : Import the saved style file. The extension is (*.ttd).

  • Export : Exports the currently selected style in the name as a (*.ttd) file.

Row Table Settings

image-20240620-075328.png

Row Table Settings

  • Station
    : Set the station to generate the Tendon coordinates.
    Based on the path referenced by the Tendon, the location is calculated according to the Station values.

  • Alternate text
    : Entered when the user wants to replace the table column title with other text. The default is displayed as 'Station'.

  • Unit : Set the Tendon coordinate value Unit.

  • Precision : Sets the precision of Tendon coordinate values.

  • Ascending sort
    : Sorts the table so that the station values ​​are in ascending order.

  • Descending sort
    : Sorts the table so that the station values ​​are in descending order.

  • Input Multi Station
    : Used to input multiple Station values ​​in batches.
    For example, it is used when the user wants to automatically input the Station value in 1-meter intervals from 1 to 100 meters.

    Station Range : Enter the start and end values ​​for Station.

    Interval : Enter an interval value to increase the value of the Station.

Column Table Settings

image-20240620-075332.png

Column Table Settings

  • Column
    : Displays Tendon coordinates in Tendon Name order or Prestressing Number order.

  • Alternate text
    : Entered when the user wants to replace the table column title with other text. The default is displayed as 'Tendon Name'.

  • Row/Column Switching
    : Swap rows and columns. In the Tendon Coordinate Table, by default, the Station is displayed in the row and the coordinates for each tendon are displayed in the column.
    When this option is selected, the rows and columns are reversed.

  • Ascending sort
    : Sorts the table so that the value used as the Tendon Name is in ascending order.

  • Descending sort
    : Sorts the table so that the value used as the Tendon Name is in descending order.

  • Alternate Text (Start/End Anchor)
    : Enter the value of the anchorage angle to change the column title when displaying the table.

  • Angle Precision
    : Sets the accuracy of the anchorage angle.

Tendon Settings

image-20240620-075339.png

Tendon Settings

Info

This feature selects the Tendon to create the Table.

  • Select Object
    : Creates only the selected Tendon as a Table.

  • Select View
    : Creates a Tendon Table in the selected View.

  • All Tendons in current view group
    : Creates a Table with all Tendons in the current workspace (based on Tab).

  • All Tendons
    : All Tendons in the linked CIM model are created in a Table.

Layer and Text Style Settings

image-20240620-075347.png

Layer and Text Style Settings

Info

Set Font and Text size and color.

  • Column Title
    : Set the text size, font, and color of the table column title.

  • Table Data
    : Set the text size, font, and color of table column title.

Option Settings

image-20240620-075352.png

Option Settings

Info

Set various option values ​​in Tendon Coordinate Table.

  • Right justifies the number
    : Displays the contents of numbers in a right-justified manner in the Cell.

  • Make a separated table in Y, Z coordination
    : Tendon Y and Z coordinates are created as separate tables.

  • Show Anchorage Angle
    : Shows the angle of anchorage in the table.

  • Make a Circle in Prestressing Number
    : Put a circle symbol on the Prestressing Number.

  • Coordinate Unit
    : Set the Tendon coordinate value unit.

  • Coordinate Precision
    : Set the precision of Tendon coordinate values.

  • View Scale
    : Set the table scale.

Cell Margin Settings

image-20240620-075359.png

Cell Margin Settings

Info

Set the margins of cells in the table.

  • Column Title
    : Sets the margin of the column title cell of the table.

  • Table Data
    : Set the margin of the table contents cell.