Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Summary


  • Explains the object’s analysis properties.

Explanation


Element Type

Settings for 1D Element compatibility type.

  • Beam
    Compatible with beam elements.

  • Truss
    Compatible with truss elements.

  • Compression Only
    Compatible with compression-only elements.

  • Tension Only
    Compatible with tension-only elements.

  • Tension Only

    • Cable
      Tension-only elements are compatible with Elastic Catenary elements.

      • Lu
        Lu Method uses the sag length of the cable.

      • Pretension
        Pretension Method uses the tension of the cable directly.

      • Horizontal
        Horizontal Method uses the horizontal tension of the cable.

Boundary Condition

Sets the beam end connection conditions of 1D elements.

  • None
    Beam end connection conditions are not considered (Hinges, etc.)

  • Release
    Beam end connection conditions are considered (Hinges, etc.)

    • Fx
      Check the box to disable axial forces at the beam end, and input Partial Fixity as needed.

    • Fy
      Check the box to disable y-axis direction shear forces at the beam end, and input Partial Fixity as needed.

    • Fz
      Check the box to disable z-axis direction shear forces at the beam end, and input Partial Fixity as needed.

    • Mx
      Check the box to disable torsional moment at the beam end, and input Partial Fixity as needed.

    • My
      Check the box to disable y-axis torsional moment at the beam end, and input Partial Fixity as needed.

    • Mz
      Check the box to disable z-axis torsional moment at the beam end, and input Partial Fixity as needed.

Mesh Size

Settings for the Auto Mesh interval length that is applied when creating the analysis model.

  • Custom Size Control

    • Off
      Individual interval length settings are not applied.

    • On
      Individual interval length settings are applied.

      • Interval Length
        Input the interval length.

      • Number of Divisions
        Input the number of divisions.

Info

Global mesh settings are applied to members without Custom Size Control from the Analysis Case feature.

Option

Sets the interval for Auto Mesh when creating the analysis model.

  • Section Offset from Left-Bottom
    When set to On, the member’s cardinal point properties are set to Left-Bottom when linked to midas Civil. The cardinal point is set to Left-Bottom regardless of the existing cardinal point of the member. The offset value is set automatically when creating the analysis model to maintain the relative position of the cross-section and the geometric line of the member.

Expand
titleDetailed Explanation (Section Offset from Left-Bottom)

왼쪽과 같은 부재를 생성한 후

After creating the member as shown in the left, turn On the Section Offset from Left-Bottom 옵션을 On하여 해석 연동 시 오른쪽과 같은 모델이 생성됩니다. 단면과 부재 기하선(Element)의 상대적인 위치가 유지되기 위하여 위의 경우 Horizontal 방향으로 0.2m, Vetical 방향으로 0.3m의 Offset이 자동으로 계산되어 입력되었습니다option to create the model in midas Civil as shown on the right when performing analysis interlocking. In order to maintain the relative position of the cross-section and the member geometry, an offset of 0.2m in the Horizontal direction and 0.3m in the Vertical direction was automatically calculated and entered.